PULTG Series UL Listed Liquid Tight Flexible Metal Conduit | Kaiflex - UL360 Certified

Feature

  • Material:

    Material:

    Galvanized Steel + PVC Jacket
  • Temperature Range:

    Temperature Range:

    -10℃~+105℃ Dry, 60℃ Wet, 70℃ Oil
    -10℃~+80℃ Dry, 60℃ Wet, 70℃ Oil
    -10℃~+60℃ Dry, 60℃ Wet, 60℃ Oil
  • IP Rating:

    IP Rating:

    IP 40 (Fit with connector series: S52)
    IP 66 (Fit with connector series: S50, S51 & S53)
  • Flexibility:

    Flexibility:

    Medium
  • Fire Retardant :

    Fire Retardant :

    Self-extinguishing
  • Standard:

    Standard:

    ANSI/UL 360, CSA 22.2 No. 56-17
  • Certificate:

    Certificate:

    UL, cULus (for 60 Dry, 60 Wet, 60 Oil only)

Parameter


Nominal Conduit SizeNominal Conduit SizePart NumberID (mm)OD w/Jacket (mm)Bending Radius (mm)Package/Roll (ft/m)Measurement (LxWxH mm)CertificateMated With
123/8PULTG1-3/812.29~12.8017.50~18.0060.8100 / 30.5440*440*14032d4255c1c940c50ac46daf8d94e7c56.png            LIQUID TIGHT FLEXIBLE METAL CONDUIT FITTING (UL 514B)            
161/2PULTG1-1/215.80~16.3120.80~21.3092.55100 / 30.5440*440*16032d4255c1c940c50ac46daf8d94e7c56.png            LIQUID TIGHT FLEXIBLE METAL CONDUIT FITTING (UL 514B)            
213/4PULTG1-3/420.83~21.3425.20~26.70117.95100 / 30.5500*500*18032d4255c1c940c50ac46daf8d94e7c56.png            Liquid Tight Conduit Fitting            
271PULTG1-126.44~27.0832.80~33.40175.1100 / 30.5600*600*30032d4255c1c940c50ac46daf8d94e7c56.png            Liquid Tight Conduit Fitting            
351-1/4PULTG1-1-1/435.05~35.8141.40~42.20213.250 / 15.3750*750*13032d4255c1c940c50ac46daf8d94e7c56.png            Liquid Tight Conduit Fitting            
411-1/2PULTG2-1-1/240.01~40.6447.40~48.30238.650 / 15.3750*750*25032d4255c1c940c50ac46daf8d94e7c56.png            Liquid Tight Conduit Fitting            
532PULTG2-251.31~51.9459.40~60.30292.625 / 7.6900*900*12032d4255c1c940c50ac46daf8d94e7c56.png            Liquid Tight Conduit Fitting            
632-1/2PULTG2-2-1/262.99~63.6372.10~73.00381.325 / 7.61000*1000*15032d4255c1c940c50ac46daf8d94e7c56.png            Liquid Tight Conduit Fitting            
783PULTG2-377.98~78.7487.90~88.90454.525 / 7.61100*1100*18032d4255c1c940c50ac46daf8d94e7c56.png            Liquid Tight Conduit Fitting            
913-1/2PULTG2-3-1/288.90~89.92100.6~101.651825 / 7.61125*1125*23032d4255c1c940c50ac46daf8d94e7c56.png            Liquid Tight Conduit Fitting            
1034PULTG2-4101.60~102.62113.30~114.30619.625 / 7.61125*1125*23032d4255c1c940c50ac46daf8d94e7c56.png            Liquid Tight Conduit Fitting            

Frequently Asked Questions (FAQ)


Q1: What makes the PULTG Series different from standard liquid-tight conduits?
A: The PULTG Series is specifically UL 360 Listed, meeting rigorous safety standards for crush resistance and tension. Unlike generic conduits, it is engineered for Hazardous Locations (Class I, II, III), ensuring NEC compliance in volatile environments.


Q2: Is this conduit suitable for outdoor and marine applications?
A: Yes, absolutely. It features a high-quality UV-resistant and oil-resistant jacket, making it the ideal choice for shipyards, offshore platforms, and outdoor power plants.


Q3: What is the voltage rating for the PULTG Series?
A: This series is rated for the protection of electrical circuits with 600 Volts or lower, providing a secure, grounded pathway for industrial wiring.


Q4: Can I use standard fittings with the PULTG Series?
A: To maintain liquid-tight integrity and NEC compliance, we recommend using Kaiflex UL-listed liquid-tight fittings specially designed for this series.


Q5: Does the PULTG Series support use in high-temperature environments?
A: Yes, the PULTG Series has an excellent industrial working temperature range. Please refer to our Technical Datasheet for precise limits by size.



UL 360 Conduit Applications

Our liquid tight flexible metal conduit systems are trusted across industries: 


 Industrial Facilities:

Chemical plants, oil refineries, and manufacturing floors where exposure to oils, coolants, and chemicals requires robust protection with UL 360 certification. 

 

Commercial Buildings:

Office complexes, retail spaces, and high-rise buildings requiring NEC-compliant wiring protection with aesthetic appeal (computer blue option available). 

 

Outdoor Installations:

Weather-exposed electrical runs, rooftop equipment connections, and exterior lighting systems benefiting from IP66 moisture protection and UV-resistant jacketing. 

 

Data Centers:

Server rooms and IT infrastructure utilizing PCBLTG computer blue series for enhanced cable identification and organization. 

 

Marine & Coastal:

Shipyards, docks, and waterfront facilities where saltwater corrosion resistance and waterproof sealing are critical.

Document

Looking for high-fit metal or non-metal conduits and fittings?

Looking for high-fit metal or non-metal conduits and fittings?
+86-563-6636999
+86-563-6636999
 info@flexible86.com
info@flexible86.com
增长建设站
Get a quote

Get a quote

We are always available to answer any questions.

Customize for You

Customize for You

Help customers save 30% costs on average
Reduce failure rates by 40% on average