Feature
-
Structure/Material:
Insulating Liner + Stainless Steel Inner Core + Stainless Steel Braid -
Conduit Size:
2-1/2"~4" -
Conduit Length (L):
Certified max. length is 36” -
Compression Strength:
Max. 512 psi (2-1/2"~4") -
Thread:
NPT, M -
RoHS:
Yes -
Certificate:
IECEx (IECEx UL 20.0075U), ATEX (DEMKO 20 ATEX 2393U), TS (TD09002U) -
IEC 60079
Size:2-1/2″ ~ 4″
Ex db ⅡC Gb
Ex tb ⅢC Db
-
ATEX
Size:2-1/2″ ~ 4″
Ⅱ 2G Ex db ⅡC Gb
Ⅱ 2D Ex tb ⅢC Db
Parameter
Ordering Information
| Conduit Length (L) | Thread | Nominal Size (inch) | Min. Radius of Bend (mm) | Part Number | |||||
|---|---|---|---|---|---|---|---|
| 2-1/2" [N] | 3a" [N] | 4" | |||||
| 406mm | 458mm | 762mm | |||||
| 18" | M | KF--GJH7F1811 | KF--GJH8aF1811 | KF--GJH9F1811 | |||
| NPT | KF--GJH7F1821 | KF--GJH8aF1821 | KF--GJH9F1821 | ||||
| 21" | M | KF--GJH7F2111 | KF--GJH8aF2111 | KF--GJH9F2111 | |||
| NPT | KF--GJH7F2121 | KF--GJH8aF2121 | KF--GJH9F2121 | ||||
| 24" | M | KF--GJH7F2411 | KF--GJH8aF2411 | KF--GJH9F2411 | |||
| NPT | KF--GJH7F2421 | KF--GJH8aF2421 | KF--GJH9F2421 | ||||
| 27" | M | KF--GJH7F2711 | KF--GJH8aF2711 | KF--GJH9F2711 | |||
| NPT | KF--GJH7F2721 | KF--GJH8aF2721 | KF--GJH9F2721 | ||||
| 30" | M | KF--GJH7F3011 | KF--GJH8aF3011 | KF--GJH9F3011 | |||
| NPT | KF--GJH7F3021 | KF--GJH8aF3021 | KF--GJH9F3021 | ||||
| 33" | M | KF--GJH7F3311 | KF--GJH8aF3311 | KF--GJH9F3311 | |||
| NPT | KF--GJH7F3321 | KF--GJH8aF3321 | KF--GJH9F3321 | ||||
| 36" | M | KF--GJH7F3611 | KF--GJH8aF3611 | KF--GJH9F3611 | |||
| NPT | KF--GJH7F3621 | KF--GJH8aF3621 | KF--GJH9F3621 | ||||
1. What is an explosion proof flexible coupling?
An explosion proof flexible coupling is a conduit component designed to prevent flame propagation while allowing flexible connections in hazardous areas.
2. Where are explosion proof couplings used?
They are commonly used in oil and gas, petrochemical, and industrial environments where explosive gases or vapors are present.
3.Why is flexibility important in hazardous area conduit systems?
Flexibility helps absorb vibration and movement, reducing mechanical stress and preventing damage to conduit connections.
4. What certifications are required for hazardous area products?
UL and IECEx are widely recognized certifications that ensure compliance with safety standards for explosion-proof equipment.
5.Is explosion proof flexible coupling suitable for offshore use?
Yes, it is designed for harsh environments including offshore platforms, where both explosion protection and durability are required.
Related Products
Document
Relevant Cases
Looking for high-fit metal or non-metal conduits and fittings?